skip to Main Content

Support

ACO’s Technical Services department offers obligation free advice to ensure the correct product is chosen.

Extensive research and development, both independently and in conjunction with leading academic institutions and research bodies, is the cornerstone of ACO’s success.

DriveDrain®

DriveDrain installation guidance

  1. Prepare a trench 200mm wide by 200mm deep. Fix a line along the trench at required finished height. Lay a bed of good quality concrete in the trench.
  2. Knock out the preformed outlet in the base of the channel or sump unit or fit a spigot stop end.
  3. Position outlet channel or sump unit in the concrete bed and ensure it is level. Connect to the drain or soakaway.
  4. Lay the remaining channels starting at the water outlet point. Hold each channel horizontally when lowering into the interlocking joint. Fit end caps.
  5. Position grates and surround channels with concrete haunching. Paving bricks should be laid in a bed of mortar.
  6. Ensure the finished paving is 2-3 mm higher than the grates to assist drainage into the channel.

If required, ACO strongly recommends wet cutting, wet drilling and/or wet grinding of polymer concrete products in a well ventilated area with the use of personal protective equipment (including masks).

 

HomeDrain® Pits

Point Drain installation guidance

Plastic Sumps

  1. Excavate a hole to the required depth
  2. Cut sump with sharp knife or hacksaw to fit drainage pipe
  3. Position sump on sand bed or mortar.
  4. Connect the drain pipework to sump
  5. Backfill and make good surrounding area.

'Polycrete' Sumps

    1. Excavate a hole to the required depth.
    2. For pipe entry or exit, cut a hole of the required diameter in the plastic insert
    3. Lay the sump on sand bed or concrete if sump will be exposed to vehicular traffic
    4. Connect drainage pipework to sump and seal joint.
    5. Backfill and make good surrounding area.

      If required, ACO strongly recommends wet cutting, wet drilling and/or wet grinding of polymer concrete products in a well ventilated area with the use of personal protective equipment (including masks).

DrainLine 100

drainline installation 1-3

1. Excavate area to accommodate trench drain and 100 mm concrete surround.
2. Pour concrete bed 300 mm wide by 100 mm deep; keep outlet pipe clean.
3. Lay channels starting at outlet. Set a string line at required height to ensure level. Seal joints if required.

drainline installation 4-6

4. Fit end caps and insert grates. To keep concrete from getting onto grates or seam, protect grates with plastic.
5. Install pavers or finish pavement surround to required level, 3 mm above grate.
6. Clean away debris, remove protective plastic.

For driveway applications, trench drain must be surrounded by 100 mm of concrete.

If required, ACO strongly recommends wet cutting, wet drilling and/or wet grinding of polymer concrete products in a well ventilated area with the use of personal protective equipment (including masks).

HexaLine 100

hexaline installation 1-3

1. Excavate area to accommodate trench drain and 100 mm concrete surround.
2. Rough in 75 mm or 100 mm outlet pipe, compact excavation base and lay 100 mm deep concrete bed.
3. Knockout channel base for outlet.

hexaline installation 4-6

4. Lay channels working away from outlet, channels slide-fit together.
5. Pour 100 mm concrete around channel sides allowing for pavement detail.
6. Finish pavement, pavers must be 3 mm higher than the grate.

For pedestrian only applications, trench drain can be set directly on well compacted soil. For driveway applications, trench drain MUST be surrounded 100 mm of concrete.

SUBSCRIBE
Close
SUBSCRIBE
Close
Back To Top